| STRUCTURE |
| |
|
|
| Structure |
|
RCC flat and column structure with brick/concrete block partitions to maximise clear spans |
| Esclators |
|
Connecting Retail Floors |
| Elevators |
|
4Passenger elevaters with separate service elecators |
| |
|
2Passenger elevators exclusive for retails floors |
| Floor to Floor Heights |
|
Retail floors 4.5m
Office floor 3.75m |
| |
|
|
| FINISHES |
| External Cladding |
|
Combination of glass curtain wall alluminium panel and polished stone |
| Flooring |
Lobbies
Basement
Tenant floor finish |
Combination of Marble,granite/Ceremic Tile
Brushed concrete
Concrete Floor |
| Toilets |
|
Finished Toilets with modern fittings and fixtures |
| Lobby |
|
Full height glaxing in Front
Wood panelling on rest of the wall
Marble/granite flooring
Custom lighting |
| Typical Core Finish |
|
Plasterboard/masoney/concrete painted
Stainless steel ironenongery
Veneered timber doors |
| PARKING |
| Parking |
|
3-Level basement for parking and services Adequate surface parking.
Provision for access control and Video servilence. |
| SECURITY |
| Video Serivilence |
|
External access points
Car park areas
Atrium/Lobby
Passenger lift cab
Option for connection of camera in tenant's lift lobby |
|
Manned Security |
|
At allentry, exit points and patrol as needed |
| Lift Safety |
| Wet Riser/Hose Reels |
|
Located near each staircase |
| Sprinklers |
|
Fully provided in landlord's premises and primary distribution each floor. Tap off points available for Secondary distribution. |
| Fire Hydrants |
|
Provided at ground level as per design |
| Hand-held Extinguishers |
|
Provided as required in landlord's areas |
| Fire Detection |
|
Main alarm panels, break glass contacts,smoke and heat derectors provided within all public and landlord's areas. Provision of connection from tenant's area to main system. |
| HVAC |
| HVAC Systems |
|
Central Chiller systems with seprate AHUs for each unit and common areas |
| BMS and controls |
|
Systems monitoring the principle operations of the builing, Control system fully integrated with the security, fire alarm and lift control systems |
| ELECRICAL |
| Electrical Fibers |
|
Provided |
| Distribution Boards |
|
Feeds, splitters and panel boards serving tenant from load side provided all wiring till entry to tenant's premises |
| Metering |
|
Metering split into common loads and tenant loads which will be sub-metered |
| Lighting Protection & Earthing Pits |
|
Lightning pits provided for base building, Provision for tenant connection to earthing pits. |
| Fire Alarm System |
|
Main alarm panels,break glass contacts, smoke and heat detectors provided within all public and landlord's areas, Provision of connection from tenant's area to main system. |
| Emergency Lighting |
|
Emergency Light fixtures (connected to landlord's UPS) provided on escape route and at all means of egress. |
| DG |
| Diesel Generators |
|
100% fully automatic backup provided for lighting, power and AC |
| Features |
|
Automatic voltage regulator, PLC based auto-starting, auto-load balancing AMF panel system provided |
| SIGNAGE |
| Internal |
|
Main lobby equipped with Tenant Directory and directional Signs, Utitlity and emergency signage where appropriate |
| External |
|
External Signage as per developers design and conditions |
| COMMUNICATION |
| Satellite Connection |
|
Spatial and structural provision for installing satellite dish on roof, Spatial provision for cables from dish to tenant's area |
| Voice and Data Risers |
|
Risers and cable trays provided |
| Telephone Incomer |
|
Cabling from junction box to tag blocks at each floor |
| LANDSCAPE |
| Roadways & Surface Parking |
|
Asphalt and interlocked precast pavers/stone cobbles as per design |
| Pedestrian and Roadway Lighting |
|
Pole and bollard mounted fixtures |
| Building Facade Lighting |
|
Feature lighting of facade with fixtures conceated within landscaped areas |
| Site Landscape |
|
Landscape garden with decorative features as per design |